Summary
Overview
Work History
Education
Skills
Additional Information
Interests
Was A great Player Of cricket
Timeline
Generic
QADEER Sadiq

QADEER Sadiq

Power & Utility Supervisor Operation And Maintenance
Lahore

Summary

Supervise and monitor the control room and field operator activities in order to ensure continued operation of the GTG/HRSG plant in a safe and reliable manner and production of uninterrupted supply of electric power.

§ Participate in the plant start up, normal operation shut down to facilitate maintenance works, includes ensuring safety, proper isolation, testing, etc. to ascertain the problem has been resolved, normalizing the unit and bringing it back on line. Liaise with LDC regarding load/production requirements.

§ Respond to emergency situations such as tripping, run back of unit, etc. trouble shoots problem and take appropriate corrective steps to normalize the unit. Report to Shift Charge

§ Participate in restoration of the plant after Black-Out. With full own responsibility

§ Review log book from previous shift to determine condition/status of each unit. Follow up on existing problems and progress corrective steps throughout the shift to reach resolution of problem.

§ Raise notification – via SAP – to maintenance on problems that occur during the shift and communicate directly with Maintenance if the problem is considered priority i.e. affects power load generation to take urgent action.

§ Issue Permit to Work and Safety Tags to carry out the required maintenance work – includes isolation of problem areas and perform electrical switching as may be needed.

§ Fully responsible to make new Electrical switching procedure in short time. High Tension Side or Low-Tension Side

§ Emergency start up procedure of Gtg unit or Hrsg unit (Heat Recovery steam Generator)

§ Review Control Room and Field Operators log sheets to determine if they were completed accurately and whether or not there are deviations from standard parameters.

§ Tour plant to determine general status of the equipment and overall readiness of the plant and identify safety infractions, if any, take appropriate action and to report to supervisor accordingly.

§ Participate in daily meetings with Operation, Maintenance and Engineering to discuss maintenance issues, status of plant and plan of action and steps to be taken.

§ Entering all required data in GTG Daily statistical report after midnight then make sure that report is complete in correct manner and aligned with ECRA definition.

§ Supervise and participate in weekly and monthly routine tests and check-ups, such as testing the Black Start Diesel Generator, Hydrogen Plant Changing-Over of auxiliaries, electrical switchgear, etc.

§ Participate in the plant start-up, normal operation shut down to facilitate maintenance works, includes ensuring safety, proper isolation, testing, etc. to ascertain the problem has been resolved, normalizing the unit and bringing it back on line. Liaise with (LDC) Load dispatch centre regarding load/production and requirements.

§ Start up The Hydrogen plant as requirement for the cooling purpose of Generators.

§ Routine changeover of Auxiliaries Cooling water pump, boiler feed water pumps, chilled water pump.

§ Check lab report hourly and start of the shift for deaerators. boilers. Cooling water system and prepared the chemical for adjust the chemical parameters.

§ Start up and shut down HRSG Units also change over the Hrsg as per requirements

§ Plan, supervise and coordinate all activities in the assigned area to meet functional objectives.

§ Train and develop the assigned staff on relevant skills to enable them to become proficient on the job and deliver the respective section objectives.

§ implement approved Department / Section policies, processes, systems, standards and procedures in order to support execution of the Department / Section’s work programs in line with Company and International standards.

§ Comply with all applicable legislation and legal regulations.

§ Maintenance and update the management budget, equipment and materials

§ Conduct regular service and systems audit

§ Guide and upgrade staff technical and management competency

§ Prepare site standard operating procedures (SOPs)

§ Generate, collate and submission of monthly reports

§ Oversee the submission of claims

§ Conduct and review plant operation, emergency plan and contingency plan

§ Conduct daily operation pass-down meeting and update staff of major works, project activities or organization goals

§ Review work request, approval and issuing work order, ensure work on time schedule

§ Manage expenditure against budget

§ Training and development of staff

§ Provide effective technical advised and solution to client

§ Introduce continued improvement and optimization operation of Facility systems

§ Perform emergency support duty, if required Enforces and adopts safety measures among all of his subordinates

§ To assist in the Planning, coordinating and controlling all operational activities in accordance with pre-arranged operating plan and programs.

§ Assist in the Operational execution according to the Contract Documents.

· Maintain Inverters and UPS, Transformers, Battery Chargers

· Inspect Direct Current Ground Detector, Lead-Acid Batteries, Vacuum Circuit Breakers,480V load circuit breaker (LC), Medium Voltage Switchboards, Reactor Trip Switchgear (RTSG), Motor Control Centers (MCC), Electrical Penetrations

· Pressurizer Heaters, Pressurizer Heater Control Panel

· Medium Voltage Motors, Emergency Diesel Generator

· Essential Chiller Motor, Low Voltage AC Motor

· DC motors, the control panel of the Motor Generator Set

· Generator of the motor generator set, cooling system of the Isolated Phase Bus (IPB), Heat Trace System

· Cathodic Protection System (Motor Operated Valve)

· Fuel Handling Area Monorail (Inspection). Equipment Hatch – Electrical Equipment. Plant Electrical Breaker Operation

· Fire Detection System Alarm Circuit

· Automatic Voltage Regulator System

· Main Generator: On Line Shaft Voltage and Current Monitoring Brush

· Electrical Heaters. Inspect Main Power Transformers (Main, SAT, UAT, Excitation)

· Transformer Tap Changer (On Load + Off Load)

· Personnel Airlock – Electrical Equipment

· High Tension (HT) SPV Cables and Connections

· Disassemble/Reassemble of Low Voltage AC Motors

· Disassemble/Reassemble of DC Voltage Motors

· Disconnecting/Earthing Switch

· Install Grounding Trucks and Cable, Disassemble/Reassemble Components of Inverter/UPS.Disassemble/Reassemble Components of Battery Charger, Replace Lead-Acid Battery, Commission new Lead-Acid Battery, Maintain generator exciter and conduct performance test. Overhaul Vacuum Circuit Breakers. Overhaul Reactor Trip Switchgear Breaker (RTSG)Maintain Main AC Generator, Maintain CT, PT, and neutral point transformer for Main Generator Maintain the Polar Crane, Disassembly/Reassembly of MV Motors, Disassembly and Assembly of Essential Chiller Motor

Overview

28
28
years of professional experience
7
7
years of post-secondary education
2
2
Languages

Work History

Power Plant Shift Engineer

Marafiq Power and utility company
Yanbu
09.1990 - 12.2018

28 years Working Experience with Marafiq Power and utility company for Jubail and Yanbu in Saudi Arabia As Power plant Shift supervisor operation and maintenance 1990 TO 2018. on huge capacity of 60x9 combine cycle frame 7 gas turbine & 5 heat recovery steam Mitsubishi generator,2 Hydrogen generator,2 Diesel generator of 2 mw capacity each for the black start purpose to restore the power supply

The job reports to GTG Superintendent. I am primarily responsible for ensuring smooth, safe and reliable operation of the GTG / HRSG plant and provision of uninterrupted supply of electric power.

I have the ability to do what needs to be done, to safe the power plant without influence from other people or situations. I am the person with self-motivation can find a reason and strength to complete a task,

I could help to made new plant modification according to requirements,

I could make new operation procedure, modify it for improvement,

Procedure for black start. To restore the power supply of plant after totally black out. All the switching procedures High tension side and low-tension side.2 years’ experience of solar power system, installation and designing

Education

years apprentice ship certificate in electrical field - Electrical Engineering

Government of Pakistan-Punjab
01.1980 - 01.1983

trade diploma - electrical

Government Polytechnic Institute
01.1978 - 01.1980

Higher secondary -

Multan
06.1976 - 01.1977

Certificate of training of Mark v from - SPEEDTRONIC™ Mark V Turbine Control

GE MEELSA
06.1999 - 01.2000

Boiler technology certificate on - Boiler Technology

From A Well Known Instructor From Saudi Arabia
10.2004 - 04.2005

Catholic protection training certificate Computer skill Expert in VISIO, SMART DRAW, E DRAW, sap system, Microsoft office, POWER POINT, WORD, PDF, Complete knowledge of trouble shooting A distributed control system (DCS)and UCS system Having full information, and skills to do all required trouble shooting during any emergency, analyse and solve serious problem, having a full systematic approach to problem solving that is often used to find and correct issues with complex machines, electronics, computers and software systems. Duties& responsibility Sound background of electrical equipment’s (SWGR, MCC, UPS, Transformer, Bus Duct, Grounding) installation, pre-commissioning, interlock verification & energization for115KV 13.8KV,4.16kV & 480V system. Experience in Design Review, Construction, Pre-commissioning, Commissioning, Plant start-up Having Complete knowledge of the principles of switching during emergency. change over the power supply in emergency or in routine maintenance job Familiar with Electrical installations, test & inspection MV, LV, MDB, SDBs, cables, bus bars, power lightning, electrical distribution systems, Earthling & lightening protection systems. Fully conversant with engineering & construction drawings and schematic diagram experience of instrumentation equipment’s, field instrumentation installation, configuration, calibration, testing Supervise and monitor the control room and field operator activities in order to ensure continued operation of the GTG/HRSG plant in a safe and reliable manner and production of uninterrupted supply of electric power. Participate in the plant start up, normal operation shut down to facilitate maintenance works, includes ensuring safety, proper isolation, testing, etc. to ascertain the problem has been resolved, normalizing the unit and bringing it back on line. Liaise with LDC regarding load/production requirements. Respond to emergency situations such as tripping, run back of unit, etc. trouble shoots problem and take appropriate corrective steps to normalize the unit. Report to Shift Charge Participate in restoration of the plant after Black-Out. With full own responsibility Review log book from previous shift to determine condition/status of each unit. Follow up on existing problems and progress corrective steps throughout the shift to reach resolution of problem. Raise notification – via SAP – to maintenance on problems that occur during the shift and communicate directly with Maintenance if the problem is considered priority i.e. affects power load generation to take urgent action. Issue Permit to Work and Safety Tags to carry out the required maintenance work – includes isolation of problem areas and perform electrical switching as may be needed. Fully responsible to make new Electrical switching procedure in short time. High Tension Side or Low-Tension Side Emergency start up procedure of Gtg unit or Hrsg unit (Heat Recovery steam Generator) Review Control Room and Field Operators log sheets to determine if they were completed accurately and whether or not there are deviations from standard parameters. Tour plant to determine general status of the equipment and overall readiness of the plant and identify safety infractions, if any, take appropriate action and to report to supervisor accordingly. Participate in daily meetings with Operation, Maintenance and Engineering to discuss maintenance issues, status of plant and plan of action and steps to be taken. Entering all required data in GTG Daily statistical report after midnight then make sure that report is complete in correct manner and aligned with ECRA definition. Supervise and participate in weekly and monthly routine tests and check-ups, such as testing the Black Start Diesel Generator, Hydrogen Plant Changing-Over of auxiliaries, electrical switchgear, etc. Participate in the plant start-up, normal operation shut down to facilitate maintenance works, includes ensuring safety, proper isolation, testing, etc. to ascertain the problem has been resolved, normalizing the unit and bringing it back on line. Liaise with (LDC) Load dispatch centre regarding load/production and requirements. Start up The Hydrogen plant as requirement for the cooling purpose of Generators. Routine changeover of Auxiliaries Cooling water pump, boiler feed water pumps, chilled water pump. Check lab report hourly and start of the shift for deaerators. boilers. Cooling water system and prepared the chemical for adjust the chemical parameters. Start up and shut down HRSG Units also change over the Hrsg as per requirements Plan, supervise and coordinate all activities in the assigned area to meet functional objectives. Train and develop the assigned staff on relevant skills to enable them to become proficient on the job and deliver the respective section objectives. implement approved Department / Section policies, processes, systems, standards and procedures in order to support execution of the Department / Section’s work programs in line with Company and International standards. Comply with all applicable legislation and legal regulations. Maintenance and update the management budget, equipment and materials Conduct regular service and systems audit Guide and upgrade staff technical and management competency Prepare site standard operating procedures (SOPs) Generate, collate and submission of monthly reports Oversee the submission of claims Conduct and review plant operation, emergency plan and contingency plan Conduct daily operation pass-down meeting and update staff of major works, project activities or organization goals Review work request, approval and issuing work order, ensure work on time schedule Manage expenditure against budget Training and development of staff Provide effective technical advised and solution to client Introduce continued improvement and optimization operation of Facility systems Perform emergency support duty, if required Enforces and adopts safety measures among all of his subordinates To assist in the Planning, coordinating and controlling all operational activities in accordance with pre-arranged operating plan and programs. Assist in the Operational execution according to the Contract Documents. Maintain Inverters and UPS, Transformers, Battery Chargers Inspect Direct Current Ground Detector, Lead-Acid Batteries, Vacuum Circuit Breakers,480V load circuit breaker (LC), Medium Voltage Switchboards, Reactor Trip Switchgear (RTSG), Motor Control Centers (MCC - undefined

Skills

Sound background of electrical equipment’s (SWGR, MCC, UPS, Transformer, Bus Duct, Grounding) installation, pre-commissioning, interlock verification & energization for115KV 138KV,416kV & 480V system Experience in Design Review, Construction, Pre-commissioning, Commissioning, Plant start-up Having Complete knowledge of the principles of switching during emergency change over the power supply in emergency or in routine maintenance job Familiar with Electrical installations, test & inspection MV, LV, MDB, SDBs, cables, bus bars, power lightning, electrical distribution systems, Earthling & lightening protection systems Fully conversant with engineering & construction drawings and schematic diagram experience of instrumentation equipment’s, field instrumentation installation, configuration, calibration, testing

undefined

Additional Information

  • Sadiq Power plant shift supervisor on Gas turbine Hrsg, Steam turbine, Boilers, Tell. 00923099889981 & 00923094199998 Qadeer_hoon@hotmail.com Add.210 Umar block Iqbal town Lahore Pakistan https://www.linkedin.com/in/qadeer-sadiq-8b34b55b/ Personal summary 28 years Working Experience with Marafiq Power and utility company for Jubail and Yanbu in Saudi Arabia As Power plant Shift supervisor operation and maintenance 1990 TO 2018. on huge capacity of 60x9 combine cycle frame 7 gas turbine & 5 heat recovery steam Mitsubishi generator,2 Hydrogen generator,2 Diesel generator of 2 mw capacity each for the black start purpose to restore the power supply The job reports to GTG Superintendent. I am primarily responsible for ensuring smooth, safe and reliable operation of the GTG / HRSG plant and provision of uninterrupted supply of electric power. I have the ability to do what needs to be done, to safe the power plant without influence from other people or situations. I am the person with self- motivation can find a reason and strength to complete a task, I could help to made new plant modification according to requirements, I could make new operation procedure, modify it for improvement, Procedure for black start. To restore the power supply of plant after totally black out. All the switching procedures High tension side and low-tension side.2 years’ experience of solar power system, installation and designing

Interests

Looking for new technical knowledge

Was A great Player Of cricket

I had Played under 19 in pakistan then in saudi Arabia i had played club cricket under ICC tell 2016.now i am teaching the young cricket's

Timeline

Boiler technology certificate on - Boiler Technology

From A Well Known Instructor From Saudi Arabia
10.2004 - 04.2005

Certificate of training of Mark v from - SPEEDTRONIC™ Mark V Turbine Control

GE MEELSA
06.1999 - 01.2000

Power Plant Shift Engineer

Marafiq Power and utility company
09.1990 - 12.2018

years apprentice ship certificate in electrical field - Electrical Engineering

Government of Pakistan-Punjab
01.1980 - 01.1983

trade diploma - electrical

Government Polytechnic Institute
01.1978 - 01.1980

Higher secondary -

Multan
06.1976 - 01.1977

Catholic protection training certificate Computer skill Expert in VISIO, SMART DRAW, E DRAW, sap system, Microsoft office, POWER POINT, WORD, PDF, Complete knowledge of trouble shooting A distributed control system (DCS)and UCS system Having full information, and skills to do all required trouble shooting during any emergency, analyse and solve serious problem, having a full systematic approach to problem solving that is often used to find and correct issues with complex machines, electronics, computers and software systems. Duties& responsibility Sound background of electrical equipment’s (SWGR, MCC, UPS, Transformer, Bus Duct, Grounding) installation, pre-commissioning, interlock verification & energization for115KV 13.8KV,4.16kV & 480V system. Experience in Design Review, Construction, Pre-commissioning, Commissioning, Plant start-up Having Complete knowledge of the principles of switching during emergency. change over the power supply in emergency or in routine maintenance job Familiar with Electrical installations, test & inspection MV, LV, MDB, SDBs, cables, bus bars, power lightning, electrical distribution systems, Earthling & lightening protection systems. Fully conversant with engineering & construction drawings and schematic diagram experience of instrumentation equipment’s, field instrumentation installation, configuration, calibration, testing Supervise and monitor the control room and field operator activities in order to ensure continued operation of the GTG/HRSG plant in a safe and reliable manner and production of uninterrupted supply of electric power. Participate in the plant start up, normal operation shut down to facilitate maintenance works, includes ensuring safety, proper isolation, testing, etc. to ascertain the problem has been resolved, normalizing the unit and bringing it back on line. Liaise with LDC regarding load/production requirements. Respond to emergency situations such as tripping, run back of unit, etc. trouble shoots problem and take appropriate corrective steps to normalize the unit. Report to Shift Charge Participate in restoration of the plant after Black-Out. With full own responsibility Review log book from previous shift to determine condition/status of each unit. Follow up on existing problems and progress corrective steps throughout the shift to reach resolution of problem. Raise notification – via SAP – to maintenance on problems that occur during the shift and communicate directly with Maintenance if the problem is considered priority i.e. affects power load generation to take urgent action. Issue Permit to Work and Safety Tags to carry out the required maintenance work – includes isolation of problem areas and perform electrical switching as may be needed. Fully responsible to make new Electrical switching procedure in short time. High Tension Side or Low-Tension Side Emergency start up procedure of Gtg unit or Hrsg unit (Heat Recovery steam Generator) Review Control Room and Field Operators log sheets to determine if they were completed accurately and whether or not there are deviations from standard parameters. Tour plant to determine general status of the equipment and overall readiness of the plant and identify safety infractions, if any, take appropriate action and to report to supervisor accordingly. Participate in daily meetings with Operation, Maintenance and Engineering to discuss maintenance issues, status of plant and plan of action and steps to be taken. Entering all required data in GTG Daily statistical report after midnight then make sure that report is complete in correct manner and aligned with ECRA definition. Supervise and participate in weekly and monthly routine tests and check-ups, such as testing the Black Start Diesel Generator, Hydrogen Plant Changing-Over of auxiliaries, electrical switchgear, etc. Participate in the plant start-up, normal operation shut down to facilitate maintenance works, includes ensuring safety, proper isolation, testing, etc. to ascertain the problem has been resolved, normalizing the unit and bringing it back on line. Liaise with (LDC) Load dispatch centre regarding load/production and requirements. Start up The Hydrogen plant as requirement for the cooling purpose of Generators. Routine changeover of Auxiliaries Cooling water pump, boiler feed water pumps, chilled water pump. Check lab report hourly and start of the shift for deaerators. boilers. Cooling water system and prepared the chemical for adjust the chemical parameters. Start up and shut down HRSG Units also change over the Hrsg as per requirements Plan, supervise and coordinate all activities in the assigned area to meet functional objectives. Train and develop the assigned staff on relevant skills to enable them to become proficient on the job and deliver the respective section objectives. implement approved Department / Section policies, processes, systems, standards and procedures in order to support execution of the Department / Section’s work programs in line with Company and International standards. Comply with all applicable legislation and legal regulations. Maintenance and update the management budget, equipment and materials Conduct regular service and systems audit Guide and upgrade staff technical and management competency Prepare site standard operating procedures (SOPs) Generate, collate and submission of monthly reports Oversee the submission of claims Conduct and review plant operation, emergency plan and contingency plan Conduct daily operation pass-down meeting and update staff of major works, project activities or organization goals Review work request, approval and issuing work order, ensure work on time schedule Manage expenditure against budget Training and development of staff Provide effective technical advised and solution to client Introduce continued improvement and optimization operation of Facility systems Perform emergency support duty, if required Enforces and adopts safety measures among all of his subordinates To assist in the Planning, coordinating and controlling all operational activities in accordance with pre-arranged operating plan and programs. Assist in the Operational execution according to the Contract Documents. Maintain Inverters and UPS, Transformers, Battery Chargers Inspect Direct Current Ground Detector, Lead-Acid Batteries, Vacuum Circuit Breakers,480V load circuit breaker (LC), Medium Voltage Switchboards, Reactor Trip Switchgear (RTSG), Motor Control Centers (MCC - undefined

QADEER SadiqPower & Utility Supervisor Operation And Maintenance