Dynamic and results-driven Electrical Engineer with a proven track record in 325MW Chashma
Nuclear Power Plant electrical maintenance
Armed with a comprehensive understanding of electrical systems,
control systems, and machinery specific to power generation, I bring a wealth of expertise in ensuring the
reliability, efficiency, and safety of critical infrastructure
Adept at executing preventive maintenance programs,
troubleshooting complex electrical issues, and leading cross-functional teams to deliver optimal performance
Possess a Bachelor's degree in Electrical Engineering with post graduation, professional licensure, and a
commitment to staying abreast of industry advancements
Known for strong analytical and problem-solving skills,
along with excellent communication and leadership abilities
Seeking to leverage my experience and skills in a
challenging role where I can contribute to the success and continuous improvement of electrical systems in a
dynamic work environment
Key Assignments Supervised multiple jobs related to Electrical Maintenance for 6 x RFOs for unit and unit 2
Oversaw of oil changing on main transformer of 400MVA
Supervised new winding of multiple motors of various sizes
Oversaw testing of 350Hz permanent magnet pilot exciter of main generator during RFO
Installation and commissioning of new Differential relay SPAM 150C on 4.5MW RCP Motor
Successfully led installation and functional testing of SIEMENS-SIPROTEC 47VU68 high-speed bus transfer
device (HSBT) on MV system Contributed to the green energy drive by designing 400KW grid tie inverter solar systems for office sites/
Parking areas, demonstrating the financial and environmental benefits Oversaw installation, configuration, and functional testing of SIEMENS 440/430 VFDs and 200kW INVT VFDs,
ensuring optimized performance
Installation and configuration of Motor control center based on Siemens PLC
Overhauling, cleaning of Main generator stator and rotor cooling water system components
Demonstrated expertise in testing and troubleshooting of solenoid valves, meeting tight deadlines
Commissiong of new waste water treatment facility based on Siemens PLC
Burn out Carbon brush removal, installation of Main generator of 325MVA
Installation and configuration of Hikvision CCTV system for boundary wall with external encryption module
with DC battery bank for each Camera
Installation and configuration of new Fire Alarm and extinguishing system
Risk assessment of Supcon DCS system installed for waste water system using IEC 62443 and ISO 27001
standards
Asset management of PLCs, Controllers and DCS systems as per IEC 62443 standard
Coordination and team work with external OT Auditors
Team: 25 x Engineers and Technicians.
MW Chashma Nuclear Power Plant
08.2019 - Current
Job overview
Mianwali | Country: Pakistan
Nuclear Industry OT Expert:
As a pro Cybersecurity Auditor and Governance, Risk Management, and Compliance (GRC) Expert, I performed a
pivotal function in fortifying the organization`s virtual infrastructure and making sure regulatory compliance, with
a selected recognition on ISO 27001-27005, NIST, IEC 62443, IAEA Nuclear series 33-T Guidelines and the auditing/
Implementation of Operational Technology (OT) environments
Main Responsibilities: Conducted Comprehensive Cybersecurity Audits:
Led and finished stop-to-stop cybersecurity audits, aligning with ISO 27001-27005 and NIST requirements, to
evaluate the effectiveness of protection controls, hazard control approaches, and compliance frameworks
Applied IEC 62443 requirements to mainly audit and decorate the safety of OT environments, addressing the
specific demanding situations related to commercial manipulate systems
GRC Frameworks Development and Implementation:
Spearheaded the improvement and implementation of Governance, Risk Management, and Compliance
frameworks, integrating ISO 27001-27005, NIST, and IEC 62443 requirements
Ensured seamless integration of GRC approaches into each day operations, fostering a lifestyle of non-stop
compliance and hazard focus throughout OT domains
Regulatory Compliance Management:
Successfully controlled compliance with enterprise-unique rules like IEC 62443, demonstrating a proactive and
adaptable approach
Maintained a complete information of evolving cybersecurity and facts safety laws, incorporating them into the
compliance framework
Risk Assessment and Mitigation:
Conducted in-intensity hazard assessments, leveraging ISO 27005/IEC 62443 guidelines, to identify, analyze, and
prioritize capability threats and vulnerabilities
Collaborated with cross-practical groups to enforce hazard mitigation strategies, improving the organization's
resilience to cyber threats in OT environments
Security Awareness, Training, and Standards Adherence:
Developed and brought cybersecurity focus programs, incorporating ISO 27001-27005 and NIST guidelines, to
train personnel on protection quality practices
Ensured adherence to enterprise requirements, supplying focused schooling on IEC 62443 for OT groups to
decorate their information and reaction to cybersecurity demanding situations
Incident Response and Crisis Management:
Formulated and finished incident reaction plans, aligning with NIST guidelines, making sure fast and powerful
responses to protection incidents in OT realms
Collaborated with IACS and OT groups to manipulate crises, minimizing impact, and making sure compliance
with incident reporting necessities and requirements
Summary: My tenure at public sector has not only strengthened my technical expertise in cybersecurity posture
improvement in OT domains but has also honed my strategic thinking and leadership skills in the realm of
Governance, Risk Management, and Compliance.
MW Chashma Nuclear Power Plant | 137MW Kanupp Nuclear Plant
Junior Engineer
02.2016 - Current
Job overview
City: Mianwali | Country: Pakistan
Key Assignments/Projects: Insulation Resistance, Winding DC resistance Test, Transformer turn ratio test, DC Leakage test, capacitance
and dissipation factor test of 400 MVA Transformer
Insulation Resistance, Winding DC resistance Test of 4.5MW RCP Motor on NI Side
Insulation Resistance, Winding DC resistance Test, of 3.7MW EDG
Current Injection testing using OMICRON equipment for SPAM150C Motor Relay, SPAJ142C OC/Earth Fault
Relay, SPAD346C differential Relay, RCS 885G and 985TM relays on Generator and Transformers, Micom P546
P443 Relays on 220KV TX Lines, REM 545 relays on EDG.
shift engineer
01.2002 - 01.2005
Job overview
Routine Maintenance of 220V DC and 48V DC battery bank.Documentation: Preparation of SOPs, procedures, work request and work authorization management and call
up card preparation
Standards: Working as per NFPA 70B and IEC-60300/ISO-13374 standards
Training and education of standards
to team members
Oversaw Replacement of condenser tubes during plant shutdown
Routine inspection and oversee maintenance of RBV fans on NI side
To oversee cold nitrogen based valve replacement activity on NI
Worked as shift engineer for helium leakage detection on NI side., in heavy water upgradation plant during shutdowns
(137MW Kanupp) Oversaw RCP pump seal replacement in Kanupp 137MW Candu based system
Operation: Operation of 132kV Auxiliary Substation
Operation of Generator system and steam turbine system during startup and shutdown of Plant
Worked with other divisions for leak detection on NI side of heavy water in Candu Based systems
Oversaw Overhauling of 137MW Kanupp Steam Turbine, Made: HitachiOvesaw UAT of Fukushima Emergency Engine Diesel Generators Installed on Top Floor of Turbine Hall
Testing and routine operation of Sea water emergency water pump based on trolley connected diesel
generator
Oversaw Testing and overhauling of emergency lighting diesel generators of 1MW.
Education
UET
BS from Electrical Engineering
12 Sep 2014
CHASCENT Chashma
PGTP from Power Technology
2 Jul 2017
Allama Iqbal Open University
Leadership and Management Course
Skills
SGS
City:
Islamabad Country: Pakistan
4/5
Other language(s):
English
LISTENING B1 READING B1 WRITING B1
SPOKEN PRODUCTION B1 SPOKEN INTERACTION B1
Pen Testing Training
IST
OSCP
NUST
LANGUAGE SKILLS
Mother tongue(s): Urdu
Levels: A1 and A2: Basic user; B1 and B2: Independent user; C1 and C2: Proficient user
DIGITAL SKILLS
Microsoft Office / AutoCad 2D -3D / Microsoft Powerpoint / Microsoft Excel / Microsoft Word / Google Docs
Matlab/Simulik / C Language / Javascript(Nodejs, ExpressJs) / Assembly (Assembly language) / ETAP power
System analysis / DIALuxEVO / Other: Microsoft Office, Vision & Project Applications / Industrial protocols
(Modbus RTU and TCP) / Basic network / PScad Software
HOBBIES AND INTERESTS
Hobbies
Swimming
Travelling
Table tennis
Outdoor Activities (Sports, Trekking and Hiking)
Google surfing
MANAGEMENT AND LEADERSHIP SKILLS
Leadership Skills
AIOU Leadership Course
4 x 4Q Leadership Courses
One week survival and Leadership Bootcamp
5/5
Accomplishments
KPI: Defining KPIs to achieve maximum efficiency
Procurement: Procurement of electrical spares using, spot, committee and tender purchase
QAD Coordination: Coordination with Quality Assurance Division to achieve quality as defined by Plant quality
Objective
Planning: Planning and documentation of Corrective and preventive plans
Electrical Design Engineer
AlFanar KSA [ 2 Feb 2015 – 2 Feb 2016 ]
City: Lahore | Country: Pakistan
Protection Design Engineer: Design of HV substations with respect to the scope of work and Project technical specifications (PTS)
considering post bid and pre-bid clarifications
Preparation of Base Design Package: Review of Main Switching One Line Diagram (132kV, 33KV, 13.8KV) Review of Protection Logic Diagram (132kV, 33KV, 13.8KV) Interlock Logic Plan (GIS, AIS) Automatic Bus transfer Schemes (ABTS) Automatic Capacitor Control Schemes (ACCS) Sequence of Events (SOE) Point List, Transient Fault Recorder (TFR) Point List, SAS Point Lists & Annunciation
Point list etc
Preparation of Detail Design Package: Preparation and Review of 132kV Protection and Control Panels Schematics (Line, Transformer, Busbar
protection, Tap Changers, Capacitor Bank Protection, bus transfer schemes etc.) with respect to SEC
Standards/PTS requirement
Preparation Detailed comments and Review of 132KV GIS Vendor data Preparation Detailed comments and Review of 132/13.8KV Power Transformer, OLTC and Local Control
Panels Review of Automatic Meter Reading Panel with respect to Power Quality and Revenue Metering
requirement Review of TFR Panel and SAS Interface Panel Review of 33kV/13.8kV MV Switchgear schematics Review of TFR Interface & Communication Interface Drawings, Protection Signaling Equipment (PSE) etc
Complete System Engineering i.e
Interfacing of Protection Panels, LCC, RTCC, LCP, TFR, PSE Panels MV
Switchgear etc
Preparation of Control Cable Schedule and Cable BOQ for Substation Implementation of design philosophy with respect to busbar arrangement i.e
Double busbar scheme onV level.5 Modification of Remote End Substations feeders with respect to the scope of work
Prepare As-built drawings based on the site markups and submit them to client
Project planning of all in-progress substations based on the contractor’s target dates
Ensure compliance to QMS procedure and provide regular feedback of project progress to Engineering
Manager
Projects:
380kV GIS Substation
132kV GIS Substation
132/13.8KV SS AL MAROOJ, KSA
132/13.8KV SS AL HAYER, KSA
132/13.8kV SS AL FLAJ, KSAV Remote End Modifications
Over all 5 remote end modifications under above mentioned Projects
One 33 kV substation with modification scope
Designing of Bus Bar protection Scheme for Al-Rawdah and Al-Nawdah Substation using REB500 Relay
Design Team Member for Substation at TAPA Ahmed bag Substation Kapisa Afghanistan
Design Study of 132 kV Shalimar GIS Substation Lahore Pakistan including Control, Relay and LCC Panels
Designing of Office Lighting on Dialux EVO
Power System Analysis Work:
Insulation Coordination Study of AL-Muajiz GIS Substation Yanbu Saudia Arabia, on PS CAD Including, Fast Front and Very Fast Front Overvoltage Analysis
Ferro resonance Analysis and Transient Recovery Voltage Analysis
Temporary OV (1 L-G Fault, Load Rejection) analysis
Switching OV (Line Energization, Line Energization and De Energization) Analysis
AuxiliaryControl Room Operator/Local Area Operator at CHASHMA NUCLEAR POWER PLANTAuxiliaryControl Room Operator/Local Area Operator at CHASHMA NUCLEAR POWER PLANT
Auxiliary Control Room Operator/Local Area Operator at CHASHMA NUCLEAR POWER PLANTAuxiliary Control Room Operator/Local Area Operator at CHASHMA NUCLEAR POWER PLANT
<ul>
<li>Performed preventive maintenance on industrial machinery and equipment.</li>
<li>Identified mechanical issues through visual inspection and testing of components.</li>
<li>Repaired or replaced malfunctioning parts, including motors, pumps, valves, seals, bearings.</li>
<li>Assign maintenance tasks and ensure compliance with quality standards</li>
<li>Operated hand tools to repair or replace defective parts.</li>
<li>Inspected moving parts for wear or damage on a regular basis to prevent breakdowns.</li>
<li>Dismantled defective machines and reassembled them after repairs were made.</li>
<li>Maintained records of all work performed in the form of written reports or computer logs.</li>
<li>Troubleshooted electrical control systems using schematics and other diagnostic tools.</li>
<li>Maintained a safe working environment by adhering to safety regulations and standards.</li>
<li>Reviewed schedules with the maintenance team before 5S audits</li>
<li>Conduct routine inspections of hoists and cranes for operational safety</li>
<li>Implemented solutions to prevent future problems</li>
<li>Key Equipment: Hytrol Conveyors, Automated See Grid Systems, Auto Store, Dematic Conveyors, Gorbel Hoists, and Coffin Hoists</li>
</ul> at AMENTUM<ul>
<li>Performed preventive maintenance on industrial machinery and equipment.</li>
<li>Identified mechanical issues through visual inspection and testing of components.</li>
<li>Repaired or replaced malfunctioning parts, including motors, pumps, valves, seals, bearings.</li>
<li>Assign maintenance tasks and ensure compliance with quality standards</li>
<li>Operated hand tools to repair or replace defective parts.</li>
<li>Inspected moving parts for wear or damage on a regular basis to prevent breakdowns.</li>
<li>Dismantled defective machines and reassembled them after repairs were made.</li>
<li>Maintained records of all work performed in the form of written reports or computer logs.</li>
<li>Troubleshooted electrical control systems using schematics and other diagnostic tools.</li>
<li>Maintained a safe working environment by adhering to safety regulations and standards.</li>
<li>Reviewed schedules with the maintenance team before 5S audits</li>
<li>Conduct routine inspections of hoists and cranes for operational safety</li>
<li>Implemented solutions to prevent future problems</li>
<li>Key Equipment: Hytrol Conveyors, Automated See Grid Systems, Auto Store, Dematic Conveyors, Gorbel Hoists, and Coffin Hoists</li>
</ul> at AMENTUM
Electrical/Construction Lead, Equipment Operator, Maintenance Technician, Electrical Apprentice at JoMar High VoltageElectrical/Construction Lead, Equipment Operator, Maintenance Technician, Electrical Apprentice at JoMar High Voltage